Liquid Ultrasonic Flowmeters; Design Changes to Reduce Engineering and Purchasing Costs

LCT4_0079

The adoption of ultrasonic flow meter technology into process control applications for liquids has been limited to some extent and only applied as a “flow technology of last resort”, when process conditions are beyond the capabilities of other technologies.

It seems that utilizing ultrasonic flow meters (UFM’s) may have; required more engineering hours to write the specifications, longer pipe straight-run to meet the performance requirements, and complicated the procurement process to address a flow meter system comprised of multiple components.

An additional concern is the perception that a UFM’s response time to a step change in flow-rate was too slow for control purposes, unless the computing power of a custody transfer type UFM was employed.  Because so many transit-time signals are processed by the CPU to achieve one velocity data point…if there are many “rejections” during the signal processing, the measurement update could be seconds which is a long time in the world of process control.  This problem has been solved with more powerful processors. Sample rates in current (non-custody transfer) UFM’s are 256 samples per second or more providing measurement resolution from nanoseconds 10-9 into the range of picoseconds 10-12.

Today we have UFMs available that are priced competitively and fast enough response to be used in many of the more common control applications.

What are some of the other implementation costs that manufactures can eliminate for users?

  • Compact meter body designs that reduce footprint size

PanaFlow LZCustom manufactured flow bodies often require complicated transducer installation methods and multiple components. The installed system footprint can be much smaller than the working clearance that must be provided so that the system can be serviced. For example, maybe 2′-3′ working clearance on both sides of a pipe to allow for transducer removal.

For example, a custom manufactured flow body in a 3″ nominal size with 150# ANSI flanges would be 30″ face to face and a width of 40″ versus the compact cast flow body meter with a 20″ face to face length and 13″ wide.

PanaFlow Z3 1

  • Shorter pipe straight run requirements for accuracy

While the best practice to assure a “Fully Developed Flow Profile” (for liquids) is 10 pipe diameters upstream and 5 pipe diameters downstream of straight-run pipe, multiple chordal paths and computational fluid dynamics software allow manufactures anticipate and correct for a lack of available straight-run. Today we are seeing accuracies of 0.15% – 0.50% in applications where we used to hope for 1%-2%.

LCT4 transducerThe newer compact meter body retains the advantage of a fully enclosed transducer protected from direct contact with the process fluid and is field replaceable. The small insert design eliminates buffers and reduces port effects that can reduce low flow accuracies.

  • Lower cost cast meter bodies

Custom made flow cells can offer benefits such as; the ability to meet flange specifications, biased angles of approach for transducer installation so that higher or lower than usual velocities can be measured, and a wide selection of flow body materials of construction. However for the vast majority of applications, cast meter bodies will meet the process requirements at a much lower cost with shorter lead times, no weld points and no external cables and improved accuracy statements.

 

These advancements allow ultrasonic flowmeters to be much more user friendly in implementation and a cost effective solution for process control measurements. We look forward to feedback and the user experience in real world application.

LCT4_0103[1]

Toxic Gas Detection with Enhanced Laser Diode Spectroscopy

A common problem in the oil and gas industry is unreliable readings causing false alarms that cost millions of dollars in lost revenue annually. Safety systems triggered by the detection of potentially hazardous gases typically shut down processes and facilities to prevent potential catastrophe. But when a false alarm triggers the safety system, productivity is lost while the alarm origin is investigated, false alarm status is verified, and processes are slowly brought back on-line.

High false alarm rates, slow detection and poor reliability are problems that frequently plague work site operations when dealing with traditional NDIR or LDS-based open path gas detection systems and specifically in toxic gas leak detection applications.

Sensient Fence Line

A detector with a greater detection range is generally considered an advantage, since it means greater ability to detect the hazard either earlier or from greater distances. However, it is important that the detector does not lead to an increased incidence of false alarms.

Enhanced Laser Diode Spectroscopy (ELDSTM) is a newer class of laser diode spectroscopy for gas detection that significantly increases the sensitivity and reliability of traditional laser-diode-based gas detection and measurement, even in extreme environments.

ELDSTM  laser based gas detection is gas species specific and will only respond to the target gas.

fingerprint_2

This removes any cross interference and unwanted alarms. Currently ELDSTM products are available for Ammonia, Carbon Dioxide, Hydrogen Sulfide, Hydrogen Chloride, Hydrogen Fluoride and Hydrogen Sulfide.

There is also detector capable of detecting both Hydrogen Sulphide and Methane in one device. Each of the two detection channels is configured and specific to the target gas.

Three big benefits of ELDSTM  over conventional toxic detectors are:

  • Elimination of false alarms
  • Failsafe operation
  • Reduced maintenance

 

Elimination of false alarms

Key to the elimination of false alarms is a harmonic fingerprint detection method. A Harmonic Fingerprint is a specific set of harmonic components introduced by target gas absorption where the relative amplitudes and phases of the components are known and specific to the target gas absorption line that is being scanned. This technique eliminates the distortion and interference that typically affect conventional laser diode spectroscopy (LDS). The harmonic fingerprint means that you can reliably distinguish between genuine target gas and non-target-gas effects. In addition, this technology is less prone to water vapor interference, thus reducing the negative repercussions of false alarms while improving detection capability for general plant safety.  This is a link to a short Video showing how the technology is applied.

ELDS Harmonic Fingerprint

Failsafe operation

Most fixed gas detectors do not provide the end-user with  live information on the operational status of any device where-as the ELDS uses a daily auto-self test called SimuGas which is a unique auto-test feature available on all units. This test provides daily verification of the systems operation without the need for manual intervention or the need for externally applied test gas or optical filters. As well as providing an alarm in the event of a test failure, each test result is held in an internal event log for future retrieval.

For example; a common trait of solid state semiconductor sensors is their tendency to “go to sleep” when exposed to H2S free air for prolonged periods of time while ELDS will respond to H2S after long periods of H2S free exposure.

Electrochemcial sensors are effective in detecting H2S gas, yet they are not resilient in high heat and prolonged low or high humidity conditions.

 

Reduced Maintenance

The reduction in maintenance is achieved in at least two ways. One; ELDSTM does not have any consumable parts unlike other fixed point gas detectors, which need their sensing elements replaced on a regular basis. This saves the cost associated spares and service labor.

In addition; the SimuGas auto-self test provides integral, daily auto self-testing information, negating the need for regular manual testing using test gases and all associated costs. Gas detector functional testing is the bane of operators responsible for maintaining conventional fixed gas detector systems yet it is essential for ensuring the safety integrity of an entire system. The SimuGas technology provides operators with the means to perform remote, on-command functional testing of an ELDS gas detector more easily, safely and less expensively than with traditional laser diode spectroscopy gas detector technologies or point detectors.

 

Our conclusion is the Enhanced Laser Diode Spectroscopy can be utilized to improve performance and safety of toxic gas detection systems, eliminate lost production resulting from false alarms and reduce maintenance costs. Additional information on permanent gas monitoring is available in the  MSA Gas Detection Handbook.

Please let us know what your thoughts and comments?

 

 

 

Custody Transfer Flowmeters – An Evolution in Technology

Custody Transfer (also know as Fiscal Metering) in the oil & gas industry refers to the transactional transfer of a substance, raw or refined, from one party (owner) to another.

Typically when custody transfer is taking place, the end goal is to determine the value or payment between two parties for the physical substance (gas or liquid) that has exchanged hands via pipeline. For that reason, the flow instrument that measures the total amount of product changing ownership can be viewed as a cash register between the two parties.

Flow measurements in typical process applications are focused around a repeatable value vs. direct accuracy of measurement. Meaning engineers and operators are OK with some level of inaccuracy as long as it is constant and repeatable. Because of the monetary value that changes hands in custody transfer, there can be significant fiscal risk if a measurement has even the smallest of errors.

The level of risk involved in custody transfer applications has led to the regulation of fiscal metering in the oil and gas industry by using standards developed by organizations such as; NIST, API, AGA, etc. As well as others outside of the United States.

While the number of flow meter technologies used in process control today continues to grow, not all are suitable or industry accepted for custody transfer. Here we look at 5 technologies that the petroleum industry has deemed suitable in fiscal metering applications.

Differential Pressure (orifice plates, Venturi tube, pitot tubes)

Steam - The Energy Fluid

 

  • As early as the 1920s, American Gas Association began studying custody transfer using Differential Pressure (DP) with orifice plates. DP measurements have been long used in process control, leading to an industry wide understanding of how they work and the maintenance required to ensure they are properly functioning. However, they do require regular maintenance and do not provide a wide measurement range for applications with large variance in flow rate. In addition they do not typically provide the accuracy that is required for liquid custody transfer the petroleum industry.

 

Turbine Meter

  • 1981 the AGA, Transmission Measurement Committee, published Report #7 outlining the use of turbine meter technology in gas applications. This began an industry trend of transitioning to turbine meters for fiscal metering of gases, displacing many of the DP installations. Turbine meters were able to achieve equal or greater accuracy while measuring a wider range of flow rates as well as performing well in liquid applications where orifices may not have had flexibility.

 

Positive Displacement

  • While the AGA is geared toward gas products, API tends to focus more on petroleum liquids. 1987 brought about the API publishing, MPMS 5.2; a report outlining the use of displacement flow meters in liquid hydrocarbon applications. PD meters are a great solution when used in small line sizes, and low flow rate applications. But similar to DP measurements they do create pressure drop, and because they are a mechanical technology, the moving part require regular maintenance.

 

Coriolis

  • Flow meters using the Coriolis effect measurement principle were developed as far back as the 1970s, however it was not until 2002 that the API published their acceptance of use in custody transfer applications (API, MPMS 5.6) . Today, Coriolis is a preferred technology for high accuracy flow applications because of the ability to accurately measure both liquids and gases in a large range of line sizes (<1″ to >12″), the lack of moving parts, as well as the ability to make a direct mass flow measurement.

 

Ultrasonic

  • Seen as one of the newer technologies in fiscal metering, AGA published Report #9 in 1998 outlining the use of multi-path ultrasonic flow meters in measurement of natural gas in pipelines. Ultrasonic flow meters function on transit time measurement using ultrasound, providing a velocity of a fluid being transferred. With high accuracy, high turndown ratio, and zero moving parts; they are ideal for natural gas lines ranging from 2″ to 40″ and larger. There is little to no pressure drop when using ultrasonic flow meters, which can improve the efficiency of pump stations used when transferring both liquid and gas products down pipelines.

Through development and testing, the petroleum industry has grown to accept a variety of technologies to be adequate for high the expectations of a custody transfer measurement. All these technologies have advantages along with their limitations, and each have their niche in the industry.  And while we hope you found the information in this post informative, it is also important to understand that the full scope of proper custody transfer system requires much more than simply installing a high accuracy flow meter, a complete metering system would also need to include; flow computers, provers, sample analysis, etc…and we will look at explaining more about each of these components in future nugget posts.